Leading Manufacturer of b & c novec gas suppression systems, electrical fire gas suppression system, tube based fire suppression system, novec 1230 fire suppression system, fk-5-1-12 fire suppression system in gurugram and fm 200 clean agent gas suppression systems from New Delhi.
₹ 15500 / Set Get Latest Price
| System Type | Pre Engineered |
| Capacity | 18 Kg |
| Application Area | Server Room, Electrical Room, Data Center, Control Room |
| Cylinder Capacity | 4kg |
| Design Standard | NFPA 2001, UL Listed, IS 15493 |
| Discharge Time | 10 sec |
| System Operation | Automatic |
| Pressure | 15 Bar |
| No. of Cylinders | 1 |
| Cylinder Height | 450mm |
| Cylinder Diameter | 200mm |
| Operating Temperature | 100 degree |
| Coverage Area | 1 squire mtr |
| Nozzle Type | Sidewall |
| Nozzle Material | Brass |
| Working Pressure | 25 bar |
| Nozzle Size | 35mm |
| Refill Service | Available |
| Country of Origin | Made in India |
| Make | Fire Avengers |
Minimum order quantity: 1 Set
FM 200 Suppression System in Delhi, India. Universally accepted FM 200 or ‘Factory Mutual 200’ also called heptaflouropropane is a colorless and odourless gaseous halocarbon used as gaseous fire suppression agent. FM 200 Suppression System in Delhi, India. This gas is liquefied under pressure for storage. FM 200 is most suitable for computer rooms, data centres, record rooms, banking assets, museums and archives, process, chemical and flammable storing facilities.
Fire Guards offers best quality suppression system both pre-engineered FM 200 fire suppression system that does not require distribution of pipes or just few pipes only and secondly engineered FM 200 fire suppression system which offers tailor made or specially designed structure for its application.
₹ 14000 / Piece Get Latest Price
| Packaging Type | Box |
| System type | Clean Agent Suppression System |
| Usage/Application | Industrial |
| Material | Metal Alloy |
| Fire Suppression Type | Cylinder |
| Certification | ce |
| Capacity | 4kg |
| Automation Grade | Automatic |
Minimum order quantity: 5000 Piece
₹ 50000 / Set Get Latest Price
| Extinguishing Agent | FK-5-1-12 (Novec 1230) |
| Packaging Type | Carton |
| Application | Electrical Panel, CNC Machine, Server Room / Data Center |
| System type | Clean Agent Suppression System |
| Usage/Application | Industrial |
| Brand | Fire Avengers |
| Material | Mild Steel |
| Certifications | ISO Certified, UL Listed, CE Marked |
| Fire Suppression Type | Cylinder |
| Included Components | Control Panel, Pressure Gauge, Audio-Visual Alarm, Cylinder with Agent, Valve Assembly |
| Capacity | 2 Kg |
| Automation Grade | Automatic |
Minimum order quantity: 1000 Set
A vehicle fire suppression system is a safety mechanism designed to detect and extinguish fires in vehicles, especially in environments where there's a higher risk of fire due to flammable materials, extreme operating conditions, or valuable equipment. These systems are commonly used in industries such as mining, construction, transportation, motorsports, and military applications.
🔥 Key Components of a Vehicle Fire Suppression System:Detection System:
Linear heat detectors, spot sensors, or optical flame detectors.
Automatically senses temperature rise or flames.
Control Panel:
Receives input from detectors and activates the suppression system.
May include manual activation options.
Suppression Agent:
Common agents include:
Dry Chemical (e.g., ABC powder)
Foam (for fuel fires)
Clean Agents (e.g., FM-200 or Novec 1230 – suitable for electronics)
Water mist (used in certain specialized systems)
Distribution System:
Network of pipes and nozzles to deliver the suppression agent to critical areas like the engine compartment, battery systems, or fuel storage.
Manual & Automatic Actuation:
Most systems offer both for redundancy.
Manual pull cables, push buttons, or remote controls.
Mining equipment (e.g., haul trucks, loaders)
Heavy machinery (excavators, bulldozers)
Buses & coaches
Race cars (mandated by most motorsport authorities)
Military and armored vehicles
Electric vehicles (EVs) (for battery compartment protection)
Minimizes vehicle downtime and repair costs.
Enhances operator safety.
Reduces risk of fire spreading to nearby assets.
May be required by insurance or safety regulations.
Regular inspections and testing are essential.
Systems must meet standards like:
NFPA 17/17A
FM Global
UL certification
ISO 16750 (for automotive electronics)
Local or industry-specific codes
₹ 300000 / Piece Get Latest Price
| Capacity | 80 kg |
| Pressure | 18 bar |
| No. of Cylinders | 1 |
| Cylinder Height | 5.6 foot |
| Operating Temperature | 80 degree |
| Nozzle Material | brass |
| Nozzle Size | 4 inch |
| Country of Origin | Made in India |
Minimum order quantity: 100 Piece
The FK-5-1-12 fire suppression system is a clean agent fire protection system that uses FK-5-1-12 fluid, also known by its trade name Novec™ 1230 (developed by 3M). It's widely used in environments where water from traditional sprinkler systems could damage critical equipment or irreplaceable assets.
🔍 What is FK-5-1-12?Chemical name: Dodecafluoro-2-methylpentan-3-one
Trade name: Novec™ 1230 (by 3M)
CAS number: 756-13-8
Type: Clean, gaseous fire suppression agent
Extinguishing method: Primarily via heat absorption
Ozone Depletion Potential (ODP): 0
Global Warming Potential (GWP): 1 (very low)
Atmospheric Lifetime: ~5 days (very short)
Safety Margin: Wide, for use in normally occupied spaces
Environmentally friendly: Low GWP and zero ODP
Safe for electronics: Leaves no residue; non-conductive
Human-safe: Suitable for use in occupied areas
Fast-acting: Extinguishes fires in seconds
Compact storage: Requires less space than inert gas systems
Data centers & server rooms
Archives and libraries
Museums and art galleries
Medical equipment rooms
Control rooms
Telecommunications facilities
Agent storage cylinders (with FK-5-1-12)
Discharge nozzles
Control panel
Detection system (smoke or heat detectors)
Piping network
Pressure release vents (for room integrity)
Fire is detected by a detection system (usually smoke or heat sensors).
Control panel activates and releases FK-5-1-12 into the protected area.
The agent vaporizes and absorbs heat, lowering the flame temperature below combustion point.
Fire is extinguished, and the agent dissipates without leaving residue.
Safe for humans at designed concentrations.
Should still be discharged in a controlled manner.
Room should be ventilated after discharge.
Regular system inspections (per NFPA 2001 or local standards)
Integrity testing (e.g., door fan test)
Refill and re-certify agent cylinders after use
₹ 190000 / Piece Get Latest Price
| Packaging Type | Carton |
| System type | Clean Agent Suppression System |
| Usage/Application | Industrial |
| Brand | Fire Avengers |
| Material | Mild Steel |
| Fire Suppression Type | Cylinder |
| Capacity | 60 KG |
| Automation Grade | Automatic |
Minimum order quantity: 100 Piece
The FK-5-1-12 fire suppression system is a clean agent fire protection system that uses FK-5-1-12 fluid, also known by its trade name Novec™ 1230 (developed by 3M). It's widely used in environments where water from traditional sprinkler systems could damage critical equipment or irreplaceable assets.
🔍 What is FK-5-1-12?Chemical name: Dodecafluoro-2-methylpentan-3-one
Trade name: Novec™ 1230 (by 3M)
CAS number: 756-13-8
Type: Clean, gaseous fire suppression agent
Extinguishing method: Primarily via heat absorption
Ozone Depletion Potential (ODP): 0
Global Warming Potential (GWP): 1 (very low)
Atmospheric Lifetime: ~5 days (very short)
Safety Margin: Wide, for use in normally occupied spaces
Environmentally friendly: Low GWP and zero ODP
Safe for electronics: Leaves no residue; non-conductive
Human-safe: Suitable for use in occupied areas
Fast-acting: Extinguishes fires in seconds
Compact storage: Requires less space than inert gas systems
Data centers & server rooms
Archives and libraries
Museums and art galleries
Medical equipment rooms
Control rooms
Telecommunications facilities
Agent storage cylinders (with FK-5-1-12)
Discharge nozzles
Control panel
Detection system (smoke or heat detectors)
Piping network
Pressure release vents (for room integrity)
Fire is detected by a detection system (usually smoke or heat sensors).
Control panel activates and releases FK-5-1-12 into the protected area.
The agent vaporizes and absorbs heat, lowering the flame temperature below combustion point.
Fire is extinguished, and the agent dissipates without leaving residue.
Safe for humans at designed concentrations.
Should still be discharged in a controlled manner.
Room should be ventilated after discharge.
Regular system inspections (per NFPA 2001 or local standards)
Integrity testing (e.g., door fan test)
Refill and re-certify agent cylinders after use
₹ 15500 / Set Get Latest Price
| Packaging Type | Box |
| Fire Suppression Type | Cylinder |
| Automation Grade | Automatic |
| System type | Total Flooding System |
| Usage/Application | Industrial |
| Brand | ar fire avenger |
| Material | Mild Steel |
| Certification | all certification |
| Capacity | your recued |
Minimum order quantity: 20000 Set
Rakesh Kumar (Business Head)
AR Fire Safety Solutions
First Floor, 339, KH. No 53/3, Gali Number 10, Prashant Enclave Baprola
New Delhi - 110043, Delhi, India